Hospital Wastewater Flow Meter 4 Inch

‎4 Inch Hospital Wastewater Flow Meter is a type of UFM flow meter or Ultrasonic Flow Meter, which is one type of flow measurement, the product we will discuss today is ‎‎Clamp On Ultrasonic Flow Meter Flowmasonic WUF 620 CF Series.‎

‎Overview of Clamp On Ultrasonic Flow Meter‎

‎Clamp on Ultrasonic Flow Meter‎‎ is a type of flowmeter that means installation without having to cut or perforate pipes. But ultrasonic or transducer sensors are quite taped on the surface outside the pipe and in the clamp. So that at the time of installation the flow in the pipe does not have to stop or the pump does not need to die or the valve does not need to be closed.‎

Flowma WUF 620 CF Series
Flowma WUF 620 CF Series

‎By cutting pipes or perforating pipes, it will hamper the production process because the flow of water must be turned off. In addition to the cost to cut or perforate pipes followed by welding, in the form of flange or expensive fittings and takes a long time. Imagine if we had to install a water flow meter on a diameter pipe above DN250, the price of flange, gasket, cutting and welding costs must be expensive.‎

‎Therefore, many engineers recommend using a type of ‎‎insertion magnetic flow meter‎‎ or type of ultrasonic clamp flow meter on. These two types of flow meters tend to be more economical when compared to the type of flow meter in line.‎

‎Read More: ‎‎Flow Meter Clamp On Ultrasonic‎

‎How to install insertion flow meter simply by perforating the pipe and installing fittings for the flow sensor (insert) mount. Furthermore, flow sensors are inserted into the pipe to detect the speed of water flow in the pipe connected with the converter or flow transmitter.‎

‎In accordance with the development of technology, many engineers also recommend using flow meters that are how to install with clamp on systems. Clamp‎‎ on installation‎‎ system is only owned by ultrasonic flow meters that have been widely applied to the type of portable flow meter. This type is usually used to check and test the performance of the system, pump equipment, maintain stability from production quality and others.‎

‎4 Inch Hospital Wastewater Flow Meter‎

‎Flowma Flowmasonic WUF 620 CF Series clamp-on transit-time ultrasonic flow meter using the transit time principle. Flowmasonic transducers are installed on the outer surface of the pipe without the requirement of flow stoppage or pipe cutting. It’s very simple, convenient for installation, calibration, and maintenance.‎

Ultrasonic Flow Meter clamp on Flowmasonic WUF 620
Clamp on Ultrasonic Flow Meter Flowmasonic WUF 620

‎Different transducer sizes meet the demand for different measurements. Plus, select the thermal energy measurement function to achieve full energy analysis. It is widely applied in processing monitoring, water balance test, district heating balance test, energy efficiency monitoring as easy installation and simple operating advantages.‎

‎Wuf Hospital Wastewater Flow Meter 620 CF Series Features‎

  • ‎4 Lines Showing Speed, Flow Rate, Volume, and Meter Status‎
  • ‎Clamp-on Mounted, Unnecessary Pipe Cutters Or Processing Interference‎
  • ‎Acceptable Liquid Temperature Range -40 °C ~ 260 °C‎
  • ‎Internal Data Storage Is Optional‎
  • ‎Choosing a PT1000 Temperature Sensor To Achieve Thermal Energy Measurement Function‎
  • ‎Suitable For Flow Measurement DN20-DN6000 By Selecting Two-Way Measurement Transducers of Different Sizes, Flow Range From 0.01m/s To 12m/s‎
Flowma WUF 620 Clamp On Ultrasonic Flow Meter
Flowma WUF 620 Clamp On Ultrasonic Flow Meter

‎When choosing a measurement location, it is important to choose an area where the fluid flow profile is fully developed to ensure highly accurate measurements. Use the following guidelines to choose the right installation site:‎

  • ‎Choose a part of the pipe that always contains liquid, such as a vertical pipe with an upward flow or a full horizontal pipe.‎
  • ‎Make sure the length of the straight pipe is at least the same as the image shown below for the installation of upstream and downstream transducers.‎
  • ‎Make sure the surface temperature of the pipe at the point of measurement is within the transducer temperature limit‎
  • ‎Pay careful attention to the condition of the inside of the pipe. If possible, choose a part of the pipe whose inside is free from corrosion or excessive crust.‎

‎Flowma WUF 620 Performance Index‎

Measuring Principle Transit-time
Velocity 0.01 – 12 m/s, Bi-directional Measurement
Resolution  0.25mm/s
Repeatability  0.1%
Accuracy ±1.0% of Reading
Response Time 0.5s
Sensitivity 0.003m/s
Damping 0-99s(settable by user )
Suitable Fluid Suitable Fluid Clean or tiny amounts of solids, air bubbles liquid , Turbidity<10000 ppm
Power Supply AC: 85-265V DC:12- 36V/500mA
Installation Wall Mounted
Protection Class IP66
Operating Temperature to +75℃
Measuring Unit meter,ft,m³,liter,ft³,gallon,barrel etc.
Communication Output 4~20mA, OCT, Relay, RS485 (Modbus-RUT), Data Logger ,GPRS
Energy Unit Unit : GJ,Opt: KWh
Security Keypad Lockout, System Lockout
Size 244*196*114mm
WB4:C22eight 2.4kg

‎Also Read: ‎‎Portable Flow Meter: Definition, Type, and Function‎

‎With the support of Flowma WUF 620 CF this can help and streamline your energy, for more information, ‎‎click here.‎‎ or want to visit the marketplace, ‎‎click disni.‎